#126 BGA footprint lacks alignment markings

Fechado
aberto por Michael Schloh von Bennewitz 4 anos atrás · 1 comentários

BGA footprint lacks alignment markings

Problem environment

The BGA footprint is challenging to populate, and can facilitate optical tests by displaying alignment markings.

Steps to reproduce

  1. Refer to the layout
  2. Locate the BGA part U3

Expected result

Alignment markings serve to guide the assembly engineer.

Actual result

No alignment markings exist in the layout design.

Severity level

This is low priority because the proposed solution does not affect function.

# BGA footprint lacks alignment markings ## Problem environment The BGA footprint is challenging to populate, and can facilitate optical tests by displaying alignment markings. ## Steps to reproduce 1. Refer to the layout 1. Locate the BGA part U3 ## Expected result Alignment markings serve to guide the assembly engineer. ## Actual result No alignment markings exist in the layout design. ## Severity level This is **low priority** because the proposed solution does not affect function.
Michael Schloh von Bennewitz adicionou a etiqueta
enhancement
4 anos atrás
Michael Schloh von Bennewitz adicionou esta issue para o marco Review of sponsorship 4 anos atrás
Michael Schloh von Bennewitz modificou o marco de Review of sponsorship para Postproject catchall 4 anos atrás

Resolved by 73a6ed9.