#127 A clock rerouted pin is not broken out

Suljettu
4 vuotta sitten avasi Michael Schloh von Bennewitz · 1 kommenttia

A clock rerouted pin is not broken out

Problem environment

The MCU clock frequency signal can be delivered to a arbitrary output pin.

Steps to reproduce

  1. Refer to the schematic
  2. Locate an easy to break out pin

Expected result

The LSE crystal frequency is rerouted to a easy to break out pin and testpoint.

Actual result

The LSE crystal frequency is not rerouted in the design.

Severity level

This is low priority because project requirements do not mandate clock calibration.

# A clock rerouted pin is not broken out ## Problem environment The MCU clock frequency signal can be delivered to a arbitrary output pin. ## Steps to reproduce 1. Refer to the schematic 1. Locate an easy to break out pin ## Expected result The LSE crystal frequency is rerouted to a easy to break out pin and testpoint. ## Actual result The LSE crystal frequency is not rerouted in the design. ## Severity level This is **low priority** because project requirements do not mandate clock calibration.
Michael Schloh von Bennewitz added the
enhancement
label 4 vuotta sitten
Michael Schloh von Bennewitz added this to the Postproject catchall milestone 4 vuotta sitten

Resolved by 73a6ed9.

Resolved by 73a6ed9.