#165 Chip antenna AE5 position is not 50Ω impedance

닫힘
Michael Schloh von Bennewitz4 년 전을 오픈 · 2개의 코멘트

Chip antenna AE5 position is not 50Ω impedance

Problem environment

For performance reasons, the chip antenna mandates a 50Ω impedance implying a track width and feed length.

Steps to reproduce

  1. Refer to the layout
  2. Locate the AE5 footprint
  3. Examine the feed track

Expected result

The AE5 chip is positioned and has tracks configured to comply with a 50Ω impedance path.

Actual result

The AE5 chip is positioned almost certainly to violate the recommended impedence.

Severity level

This is low priority because project requirements do not mandate antenna type or performance.

# Chip antenna AE5 position is not 50Ω impedance ## Problem environment For performance reasons, the chip antenna mandates a 50Ω impedance implying a track width and feed length. ## Steps to reproduce 1. Refer to the layout 1. Locate the AE5 footprint 1. Examine the feed track ## Expected result The AE5 chip is positioned and has tracks configured to comply with a 50Ω impedance path. ## Actual result The AE5 chip is positioned almost certainly to violate the recommended impedence. ## Severity level This is **low priority** because project requirements do not mandate antenna type or performance.
Michael Schloh von Bennewitz added the
bug
label 4 년 전
Michael Schloh von Bennewitz added the
help wanted
label 4 년 전
Michael Schloh von Bennewitz Postproject catchall 4 년 전 마일스톤을 추가하였습니다.
Michael Schloh von Bennewitz 코멘트됨, 4 년 전
소유자

Partially solved in c6ed8ea, pending vector network analysis and manufacturer technical support.

Partially solved in c6ed8ea, pending vector network analysis and manufacturer technical support.
Michael Schloh von Bennewitz 코멘트됨, 4 년 전
소유자

Solved near 0904bbd, with reference to manufacturer advice that ‘prioritize the antenna trace impedance as low.’

Solved near 0904bbd, with reference to manufacturer advice that 'prioritize the antenna trace impedance as low.'