#74 Traces to JP2 and JP3 are wrong

Закрито
4 роки тому відкрито Michael Schloh von Bennewitz · 1 коментарів
Michael Schloh von Bennewitz прокоментував(ла) 4 роки тому

Traces to JP2 and JP3 are wrong

Problem environment

UART connections connect half duplex signals over crossed traces, meaning a host transmits over a TX trace connected to the RX trace of a device.

Steps to reproduce

  1. Observe the schematic design
  2. Search the JP2/JP3 connectors
  3. Observe UART_TX and GPIO14/TXD

Expected result

  • UART_RX connects with GPIO14/TXD.
  • UART_TX connects with GPIO15/RXD.

Actual result

  • UART_RX connects with GPIO15/RXD.
  • UART_TX connects with GPIO14/TXD.

Workaround

The jumper layout specifies a male header, allowing to cross the connection appropriately using breadboard female wires.

Severity level

This is high priority because we expect most users to use the serial connection extensively.

# Traces to JP2 and JP3 are wrong ## Problem environment UART connections connect half duplex signals over crossed traces, meaning a host transmits over a TX trace connected to the RX trace of a device. ## Steps to reproduce 1. Observe the schematic design 1. Search the JP2/JP3 connectors 1. Observe UART_TX and GPIO14/TXD ## Expected result * UART_RX connects with **GPIO14/TXD**. * **UART_TX** connects with GPIO15/RXD. ## Actual result * UART_RX connects with GPIO15/RXD. * **UART_TX** connects with **GPIO14/TXD**. ## Workaround The jumper layout specifies a male header, allowing to cross the connection appropriately using breadboard female wires. ## Severity level This is **high priority** because we expect most users to use the serial connection extensively.
Michael Schloh von Bennewitz додано
bug
мітку 4 роки тому
Michael Schloh von Bennewitz додав(ла) до Target platform regression testing етапу 4 роки тому
Michael Schloh von Bennewitz прокоментував(ла) 4 роки тому
Власник

Resolved in 8e36a89.

Resolved in 8e36a89.