This is high priority because project requirements state panelisation which implies such tasks.
# Silkscreen designators are not fixed
## Problem environment
Panelisation often benefits from board rotation, which displays designators wrong if they are set to dynamically rotate according to an axis.
## Steps to reproduce
1. Observe the layout
1. Examine a designator reference
1. Review the reference settings
## Expected result
Each reference setting should not specify *Keep Upright*.
## Actual result
Some reference settings do specify *Keep Upright*.
## Notice
The *kicad_pcb* files can be edited to avoid time consuming manipulating with the user interface.
```
--- dscomm-file.kicad_pcb.orig 2020-11-23 18:02:36.550884189 +0100
+++ dscomm-file.kicad_pcb 2020-11-23 17:04:32.004239472 +0100
@@ -3917,7 +3917,7 @@
(tags "SPST Button Switch")
(path /5F53D5B5/5F8E32A8)
(attr smd)
- (fp_text reference SW1 (at 0 0) (layer B.SilkS)
+ (fp_text reference SW1 (at 0 0 unlocked) (layer B.SilkS)
(effects (font (size 1 1) (thickness 0.15)) (justify mirror))
)
(fp_text value SW_SPST (at 0 2.6 90) (layer F.Fab)
```
## Severity level
This is **high priority** because project requirements state panelisation which implies such tasks.
Michael Schloh von Bennewitz
ha añadido esto al hito Design panelisationhace 4 años '
issues.change_milestone_at=`modificó el hito de %!s(MISSING) a %!s(MISSING) %!s(MISSING)
Silkscreen designators are not fixed
Problem environment
Panelisation often benefits from board rotation, which displays designators wrong if they are set to dynamically rotate according to an axis.
Steps to reproduce
Expected result
Each reference setting should not specify Keep Upright.
Actual result
Some reference settings do specify Keep Upright.
Notice
The kicad_pcb files can be edited to avoid time consuming manipulating with the user interface.
Severity level
This is high priority because project requirements state panelisation which implies such tasks.