#114 C30 is placed 27pF instead of 2,7pF

Закрыто
открыта 4 лет назад Michael Schloh von Bennewitz · комментариев: 1
Michael Schloh von Bennewitz прокомментировал 4 лет назад

C30 is placed 27pF instead of 2,7pF

Problem environment

The input radio circuit between switch and transceiver is balanced by capacitors and inductors of particular qualities.

Steps to reproduce

  1. Refer to the schematic
  2. Find the C30 capacitor
  3. Read the capacitance

Expected result

The specified capacitance is 2,7pF.

Actual result

The specified capacitance is 27pF.

Severity level

This is high priority because measured reception is poor.

# C30 is placed 27pF instead of 2,7pF ## Problem environment The input radio circuit between switch and transceiver is balanced by capacitors and inductors of particular qualities. ## Steps to reproduce 1. Refer to the schematic 1. Find the C30 capacitor 1. Read the capacitance ## Expected result The specified capacitance is 2,7pF. ## Actual result The specified capacitance is 27pF. ## Severity level This is **high priority** because measured reception is poor.
Michael Schloh von Bennewitz добавил(а) метку
bug
4 лет назад
Michael Schloh von Bennewitz добавил к этапу Layout design 4 лет назад
Michael Schloh von Bennewitz прокомментировал 4 лет назад
Владелец

Resolved by 7c358dd.