#114 C30 is placed 27pF instead of 2,7pF

Закрито
4 роки тому відкрито Michael Schloh von Bennewitz · 1 коментарів
Michael Schloh von Bennewitz прокоментував(ла) 4 роки тому

C30 is placed 27pF instead of 2,7pF

Problem environment

The input radio circuit between switch and transceiver is balanced by capacitors and inductors of particular qualities.

Steps to reproduce

  1. Refer to the schematic
  2. Find the C30 capacitor
  3. Read the capacitance

Expected result

The specified capacitance is 2,7pF.

Actual result

The specified capacitance is 27pF.

Severity level

This is high priority because measured reception is poor.

# C30 is placed 27pF instead of 2,7pF ## Problem environment The input radio circuit between switch and transceiver is balanced by capacitors and inductors of particular qualities. ## Steps to reproduce 1. Refer to the schematic 1. Find the C30 capacitor 1. Read the capacitance ## Expected result The specified capacitance is 2,7pF. ## Actual result The specified capacitance is 27pF. ## Severity level This is **high priority** because measured reception is poor.
Michael Schloh von Bennewitz додано
bug
мітку 4 роки тому
Michael Schloh von Bennewitz додав(ла) до Layout design етапу 4 роки тому
Michael Schloh von Bennewitz прокоментував(ла) 4 роки тому
Власник

Resolved by 7c358dd.

Resolved by 7c358dd.
Підпишіться щоб приєднатися до обговорення.