A pin with GCLK_IO[x] functionality can be used to route GCLKx clock. In this case, we will use GCLK3 to output clock as PA17(GCLK_IO[3]) is available for probing in the design through R14(I2C_SCL).
Enable clock output by configuring GCLKx as below to enable clock output(CONF_CLOCK_GCLK_3_OUTPUT_ENABLE) for the specific GCLK. These changes are done in conf_clocks.h.
# define CONF_CLOCK_GCLK_3_ENABLE true
# define CONF_CLOCK_GCLK_3_RUN_IN_STANDBY false
# define CONF_CLOCK_GCLK_3_CLOCK_SOURCE SYSTEM_CLOCK_SOURCE_XOSC32K
# define CONF_CLOCK_GCLK_3_PRESCALER 1
# define CONF_CLOCK_GCLK_3_OUTPUT_ENABLE true
Next, I/O PA17 which has GCLK_IO[3] as one of the PINMUX needs to be configured with Pinmux function H. The following code snippet could be added in the board_init.c
struct system_pinmux_config pinmux_config;
system_pinmux_get_config_defaults(&pinmux_config);
pinmux_config.mux_position= PINMUX_PA17H_GCLK_IO3;
pinmux_config.direction = SYSTEM_PINMUX_PIN_DIR_OUTPUT;
system_pinmux_pin_set_config(PIN_PA17,&pinmux_config);
The above code changes would enable GCLK3 with XOSC32K as clock source with output enabled. The pin PA17(GCLK_IO[3]) is enabled with PINMUX function H. With these changes, the device should be able to output XOSC32K clock on PA17.
Severity level
This is low priority because project requirements do not mandate calibrated radio transception.
# Test LSE crystal circuit for best practice
## Problem environment
Crystals in radio applications play an increasingly important role at run time.
## Steps to reproduce
1. Refer to the layout
1. Use a frequency counter
1. Measure crystal circuits
## Expected result
The output of all crystals is as expected, and the circuit design follows best practices.
## Actual result
Crystal outputs is unknown pending finding a suitable measurement tool.
## Resources
https://www.murata.com/en-us/products/timingdevice/crystalu/basic/
https://ww1.microchip.com/downloads/en/AppNotes/AN2648-Selecting_Testing-32KHz-Crystal-Osc-for-AVR-MCUs-00002648B.pdf
## Instructions
```
A pin with GCLK_IO[x] functionality can be used to route GCLKx clock. In this case, we will use GCLK3 to output clock as PA17(GCLK_IO[3]) is available for probing in the design through R14(I2C_SCL).
Enable clock output by configuring GCLKx as below to enable clock output(CONF_CLOCK_GCLK_3_OUTPUT_ENABLE) for the specific GCLK. These changes are done in conf_clocks.h.
# define CONF_CLOCK_GCLK_3_ENABLE true
# define CONF_CLOCK_GCLK_3_RUN_IN_STANDBY false
# define CONF_CLOCK_GCLK_3_CLOCK_SOURCE SYSTEM_CLOCK_SOURCE_XOSC32K
# define CONF_CLOCK_GCLK_3_PRESCALER 1
# define CONF_CLOCK_GCLK_3_OUTPUT_ENABLE true
Next, I/O PA17 which has GCLK_IO[3] as one of the PINMUX needs to be configured with Pinmux function H. The following code snippet could be added in the board_init.c
struct system_pinmux_config pinmux_config;
system_pinmux_get_config_defaults(&pinmux_config);
pinmux_config.mux_position= PINMUX_PA17H_GCLK_IO3;
pinmux_config.direction = SYSTEM_PINMUX_PIN_DIR_OUTPUT;
system_pinmux_pin_set_config(PIN_PA17,&pinmux_config);
The above code changes would enable GCLK3 with XOSC32K as clock source with output enabled. The pin PA17(GCLK_IO[3]) is enabled with PINMUX function H. With these changes, the device should be able to output XOSC32K clock on PA17.
```
## Severity level
This is **low priority** because project requirements do not mandate calibrated radio transception.
Test LSE crystal circuit for best practice
Problem environment
Crystals in radio applications play an increasingly important role at run time.
Steps to reproduce
Expected result
The output of all crystals is as expected, and the circuit design follows best practices.
Actual result
Crystal outputs is unknown pending finding a suitable measurement tool.
Resources
https://www.murata.com/en-us/products/timingdevice/crystalu/basic/
https://ww1.microchip.com/downloads/en/AppNotes/AN2648-Selecting_Testing-32KHz-Crystal-Osc-for-AVR-MCUs-00002648B.pdf
Instructions
Severity level
This is low priority because project requirements do not mandate calibrated radio transception.
Test crystal circuits for best practice为 Test LSE crystal circuit for best practiceIt was determined that the optimal capacitor load is between 15pF and 20pF, as shown by the C18 and C19 values of 18pF.