#141 S11 measurements are missing

Geschlossen
vor 4 Jahren von Michael Schloh von Bennewitz geöffnet · 2 Kommentare

S11 measurements are missing

Problem environment

Antenna resonance is tuned for subgigaherz frequencies, and calibration benefits from S11 resonance testing.

Steps to reproduce

  1. Use a vector network analyser (VNA)
  2. Test for resonance in anntenae
  3. Measure S11 vector parameters

Expected result

The antenna chosen should be well calibrated according to S-parameters.

Actual result

S-parameters are unknown and measurement is missing.

Severity level

This is low priority because project requirements do not include antenna calibration.

# S11 measurements are missing ## Problem environment Antenna resonance is tuned for subgigaherz frequencies, and calibration benefits from S11 resonance testing. ## Steps to reproduce 1. Use a vector network analyser (VNA) 1. Test for resonance in anntenae 1. Measure S11 vector parameters ## Expected result The antenna chosen should be well calibrated according to S-parameters. ## Actual result S-parameters are unknown and measurement is missing. ## Severity level This is **low priority** because project requirements do not include antenna calibration.
Michael Schloh von Bennewitz fügte das
help wanted
Label vor 4 Jahren hinzu
Michael Schloh von Bennewitz fügte das
enhancement
Label vor 4 Jahren hinzu
Michael Schloh von Bennewitz hat diesen Issue vor 4 Jahren zum Postproject catchall Meilenstein hinzugefügt
Michael Schloh von Bennewitz hat vor 4 Jahren kommentiert
Besitzer

Partially solved by 5a29587.

Partially solved by 5a29587.
Michael Schloh von Bennewitz hat vor 4 Jahren kommentiert
Besitzer

This S11 reflection diagram illustrates current work on 0.9.2 after hacking a pi network onto the bare antenna feed line, which seems to indicate that the Johanson chip model datasheet estimation is close enough to implement.

S11 return loss diagram for Johanson 0868AT43A0020E

The applications engineering department at the manufacturer is informed of a request for information to further tune the Sendcomm AE2 circuit. Referring to the online manufacturer tuning guidelines has been somewhat helpful.

This S11 reflection diagram illustrates current work on 0.9.2 after hacking a pi network onto the bare antenna feed line, which seems to indicate that the Johanson chip model datasheet estimation is close enough to implement. ![S11 return loss diagram for Johanson 0868AT43A0020E](/attachments/f229164f-d872-4127-8419-46c185347f80/) The [applications engineering department at the manufacturer](https://www.johansontechnology.com/ask-a-question/) is informed of a request for information to further tune the Sendcomm AE2 circuit. Referring to [the online manufacturer tuning guidelines](https://www.johansontechnology.com/tuning/) has been somewhat helpful.