#93 The LDO at U2 is the wrong footprint

Slēgta
Michael Schloh von Bennewitz atvēra pirms 4 gadiem · 1 komentāri

The LDO at U2 is the wrong footprint

Problem environment

The low dropout voltage regulator for USB bus power according to the bill of materials must fit the layout footprint.

Steps to reproduce

  1. Reference the parts list and layout
  2. Examine the LDO with designator U2
  3. Compare the size and footprint

Expected result

The size and footprint of the part specified by the bill of materials is consistent with the layout design.

Actual result

The layout design indicates a different footprint than the bill of materials specifies.

Workaround

A nasty hand soldered fine pitch effort is possible if a high quality microscope and solder station is used. Solder the terminals of the LDO by hand.

Severity level

This is low priority because project requirements imply no support for serial interfaces, except for UART/RS232 needed for host communication.

# The LDO at U2 is the wrong footprint ## Problem environment The low dropout voltage regulator for USB bus power according to the bill of materials must fit the layout footprint. ## Steps to reproduce 1. Reference the parts list and layout 1. Examine the LDO with designator U2 1. Compare the size and footprint ## Expected result The size and footprint of the part specified by the bill of materials is consistent with the layout design. ## Actual result The layout design indicates a different footprint than the bill of materials specifies. ## Workaround A nasty hand soldered fine pitch effort is possible if a high quality microscope and solder station is used. Solder the terminals of the LDO by hand. ## Severity level This is **low priority** because project requirements imply no support for serial interfaces, except for UART/RS232 needed for host communication.
Michael Schloh von Bennewitz pievienoja etiķeti
bug
pirms 4 gadiem
Michael Schloh von Bennewitz pievienoja atskaites punktu Layout design pirms 4 gadiem

Resolved by 7c2b89e.

Resolved by 7c2b89e.
Pierakstieties, lai pievienotos šai sarunai.
Nav atskaites punktu
Nav atbildīgo
1 dalībnieki
Izpildes termiņš

Izpildes termiņš nav uzstādīts.

Atkarības

Šai problēmai pagaidām nav nevienas atkarības.

Notiek ielāde…
Atcelt
Saglabāt
Vēl nav satura.