#114 C30 is placed 27pF instead of 2,7pF

Closed
opened 3 years ago by Michael Schloh von Bennewitz · 1 comments

C30 is placed 27pF instead of 2,7pF

Problem environment

The input radio circuit between switch and transceiver is balanced by capacitors and inductors of particular qualities.

Steps to reproduce

  1. Refer to the schematic
  2. Find the C30 capacitor
  3. Read the capacitance

Expected result

The specified capacitance is 2,7pF.

Actual result

The specified capacitance is 27pF.

Severity level

This is high priority because measured reception is poor.

# C30 is placed 27pF instead of 2,7pF ## Problem environment The input radio circuit between switch and transceiver is balanced by capacitors and inductors of particular qualities. ## Steps to reproduce 1. Refer to the schematic 1. Find the C30 capacitor 1. Read the capacitance ## Expected result The specified capacitance is 2,7pF. ## Actual result The specified capacitance is 27pF. ## Severity level This is **high priority** because measured reception is poor.
Michael Schloh von Bennewitz added the
bug
label 3 years ago
Michael Schloh von Bennewitz added this to the Layout design milestone 3 years ago

Resolved by 7c358dd.