#182 Power circuits are missing from panel

Slēgta
Michael Schloh von Bennewitz atvēra pirms 4 gadiem · 1 komentāri

Power circuits are missing from panel

Problem environment

Board test and program work is most easily done in panel arrangements, where GND and 3V3 are connected once on a rail edge.

Steps to reproduce

  1. Refer to the panel layout
  2. Examine the rail edges
  3. Search for power connectors

Expected result

A general GND and 3V3 connection is available in the panel.

Actual result

No power connection is possible on panel structures.

Severity level

This is low priority because boards can be tested and programmed individually.

# Power circuits are missing from panel ## Problem environment Board test and program work is most easily done in panel arrangements, where GND and 3V3 are connected once on a rail edge. ## Steps to reproduce 1. Refer to the panel layout 1. Examine the rail edges 1. Search for power connectors ## Expected result A general GND and 3V3 connection is available in the panel. ## Actual result No power connection is possible on panel structures. ## Severity level This is **low priority** because boards can be tested and programmed individually.
Michael Schloh von Bennewitz pievienoja etiķeti
enhancement
pirms 4 gadiem
Michael Schloh von Bennewitz pievienoja atskaites punktu Postproject catchall pirms 4 gadiem

Solved in 5dd172c, but please remember to adjust new panel frames accordingly!

Solved in 5dd172c, but please remember to **adjust new panel frames** accordingly!