#6 Segregate ground planes

Geschlossen
vor 4 Jahren von Michael Schloh von Bennewitz geöffnet · 1 Kommentare

Segregate ground planes

Problem environment

Ground segregation of digital, analog, and radio circuits improves quality.

Steps to reproduce

  1. Observe ground connections at the controller and switch
  2. Compare with schematic and layout reference designs

Expected result

The ground connections should be segregated accordingly.

Actual result

The ground connections tie to a single plane.

Severity level

This is low priority because project requirements lack ground segregation.

# Segregate ground planes ## Problem environment Ground segregation of digital, analog, and radio circuits improves quality. ## Steps to reproduce 1. Observe ground connections at the controller and switch 2. Compare with schematic and layout reference designs ## Expected result The ground connections should be segregated accordingly. ## Actual result The ground connections tie to a single plane. ## Severity level This is **low priority** because project requirements lack ground segregation.
Michael Schloh von Bennewitz fügte das
enhancement
Label vor 4 Jahren hinzu
Michael Schloh von Bennewitz hat den Titel von Segregate grounds zu Segregate ground planes vor 4 Jahren geändert
Michael Schloh von Bennewitz hat vor 4 Jahren kommentiert
Besitzer

Design review indicated that ground planes can be tied together.

Design review indicated that ground planes can be tied together.