#6 Segregate ground planes

Затворено
отворено пре 4 година од Michael Schloh von Bennewitz · 1 коментара

Segregate ground planes

Problem environment

Ground segregation of digital, analog, and radio circuits improves quality.

Steps to reproduce

  1. Observe ground connections at the controller and switch
  2. Compare with schematic and layout reference designs

Expected result

The ground connections should be segregated accordingly.

Actual result

The ground connections tie to a single plane.

Severity level

This is low priority because project requirements lack ground segregation.

# Segregate ground planes ## Problem environment Ground segregation of digital, analog, and radio circuits improves quality. ## Steps to reproduce 1. Observe ground connections at the controller and switch 2. Compare with schematic and layout reference designs ## Expected result The ground connections should be segregated accordingly. ## Actual result The ground connections tie to a single plane. ## Severity level This is **low priority** because project requirements lack ground segregation.
Michael Schloh von Bennewitz added the
enhancement
label пре 4 година
Michael Schloh von Bennewitz changed title from Segregate grounds to Segregate ground planes пре 4 година
Michael Schloh von Bennewitz коментирира пре 4 година
Власник

Design review indicated that ground planes can be tied together.

Design review indicated that ground planes can be tied together.