#6 Segregate ground planes

Zamknięty
otworzone 4 lat temu przez Michael Schloh von Bennewitz · 1 komentarzy

Segregate ground planes

Problem environment

Ground segregation of digital, analog, and radio circuits improves quality.

Steps to reproduce

  1. Observe ground connections at the controller and switch
  2. Compare with schematic and layout reference designs

Expected result

The ground connections should be segregated accordingly.

Actual result

The ground connections tie to a single plane.

Severity level

This is low priority because project requirements lack ground segregation.

# Segregate ground planes ## Problem environment Ground segregation of digital, analog, and radio circuits improves quality. ## Steps to reproduce 1. Observe ground connections at the controller and switch 2. Compare with schematic and layout reference designs ## Expected result The ground connections should be segregated accordingly. ## Actual result The ground connections tie to a single plane. ## Severity level This is **low priority** because project requirements lack ground segregation.
Michael Schloh von Bennewitz dodano etykietę
enhancement
4 lat temu
Michael Schloh von Bennewitz zmieniono tytuł z Segregate grounds na Segregate ground planes 4 lat temu
Michael Schloh von Bennewitz skomentował(-a) 4 lat temu
Właściciel

Design review indicated that ground planes can be tied together.

Design review indicated that ground planes can be tied together.
Zaloguj się, aby dołączyć do tej rozmowy.
Brak kamienia milowego
Brak przypisanych
Uczestnicy 1
Termin realizacji

Brak ustawionego terminu realizacji.

Zależności

To zgłoszenie nie ma w tej chwili żadnych zależności.

Ładowanie…
Anuluj
Zapisz
Nie ma jeszcze treści.