#75 Modify header pins to solder jumpers

Fermé
créé il y a 4 ans par Michael Schloh von Bennewitz · 1 commentaires

Modify header pins to solder jumpers

Problem environment

Most of the jumper connectors are designed for header pins, useful in prototype testing. As design stabilises, header pins are less useful and design benefits from solder jumpers instead.

Steps to reproduce

  1. Observe the layout
  2. Search for jumpers
  3. Examine the bill of materials

Expected result

  • JP1: Solder jumper (no bridge)
  • JP2: Solder jumper (bridged 1,2)
  • JP3: Solder jumper (bridged 1,2)
  • J1: Solder jumper (3-way bridged 2,3)

Actual result

  • JP1: Header pins
  • JP2: Header pins
  • JP3: Header pins
  • J1: Header pins

Note

Replace with oval shaped solder jumpers rather than triangle shaped ones, to allow for zero ohm resitors to be used as bridges.

Severity level

This is medium priority because the functional and optical benefit is large.

# Modify header pins to solder jumpers ## Problem environment Most of the jumper connectors are designed for header pins, useful in prototype testing. As design stabilises, header pins are less useful and design benefits from solder jumpers instead. ## Steps to reproduce 1. Observe the layout 1. Search for jumpers 1. Examine the bill of materials ## Expected result * **JP1:** Solder jumper (no bridge) * **JP2:** Solder jumper (bridged 1,2) * **JP3:** Solder jumper (bridged 1,2) * **J1:** Solder jumper (3-way bridged 2,3) ## Actual result * **JP1:** Header pins * **JP2:** Header pins * **JP3:** Header pins * **J1:** Header pins ## Note Replace with **oval shaped solder jumpers** rather than triangle shaped ones, to allow for zero ohm resitors to be used as bridges. ## Severity level This is **medium priority** because the functional and optical benefit is large.
Michael Schloh von Bennewitz a ajouté l'étiquette
enhancement
il y a 4 ans
Michael Schloh von Bennewitz a ajouté cela au jalon Final schematic and layout design il y a 4 ans
Michael Schloh von Bennewitz a commenté il y a 4 ans
Propriétaire

Resolved by 7e32c82.

Resolved by 7e32c82.