#75 Modify header pins to solder jumpers

Chiuso
aperto 4 anni fa da Michael Schloh von Bennewitz · 1 commenti

Modify header pins to solder jumpers

Problem environment

Most of the jumper connectors are designed for header pins, useful in prototype testing. As design stabilises, header pins are less useful and design benefits from solder jumpers instead.

Steps to reproduce

  1. Observe the layout
  2. Search for jumpers
  3. Examine the bill of materials

Expected result

  • JP1: Solder jumper (no bridge)
  • JP2: Solder jumper (bridged 1,2)
  • JP3: Solder jumper (bridged 1,2)
  • J1: Solder jumper (3-way bridged 2,3)

Actual result

  • JP1: Header pins
  • JP2: Header pins
  • JP3: Header pins
  • J1: Header pins

Note

Replace with oval shaped solder jumpers rather than triangle shaped ones, to allow for zero ohm resitors to be used as bridges.

Severity level

This is medium priority because the functional and optical benefit is large.

# Modify header pins to solder jumpers ## Problem environment Most of the jumper connectors are designed for header pins, useful in prototype testing. As design stabilises, header pins are less useful and design benefits from solder jumpers instead. ## Steps to reproduce 1. Observe the layout 1. Search for jumpers 1. Examine the bill of materials ## Expected result * **JP1:** Solder jumper (no bridge) * **JP2:** Solder jumper (bridged 1,2) * **JP3:** Solder jumper (bridged 1,2) * **J1:** Solder jumper (3-way bridged 2,3) ## Actual result * **JP1:** Header pins * **JP2:** Header pins * **JP3:** Header pins * **J1:** Header pins ## Note Replace with **oval shaped solder jumpers** rather than triangle shaped ones, to allow for zero ohm resitors to be used as bridges. ## Severity level This is **medium priority** because the functional and optical benefit is large.
Michael Schloh von Bennewitz added the
enhancement
label 4 anni fa
Michael Schloh von Bennewitz aggiunta alle pietre miliari Final schematic and layout design 4 anni fa
Michael Schloh von Bennewitz 4 anni fa ha commentato
Proprietario

Resolved by 7e32c82.