#75 Modify header pins to solder jumpers

Zamknięty
otworzone 4 lat temu przez Michael Schloh von Bennewitz · 1 komentarzy

Modify header pins to solder jumpers

Problem environment

Most of the jumper connectors are designed for header pins, useful in prototype testing. As design stabilises, header pins are less useful and design benefits from solder jumpers instead.

Steps to reproduce

  1. Observe the layout
  2. Search for jumpers
  3. Examine the bill of materials

Expected result

  • JP1: Solder jumper (no bridge)
  • JP2: Solder jumper (bridged 1,2)
  • JP3: Solder jumper (bridged 1,2)
  • J1: Solder jumper (3-way bridged 2,3)

Actual result

  • JP1: Header pins
  • JP2: Header pins
  • JP3: Header pins
  • J1: Header pins

Note

Replace with oval shaped solder jumpers rather than triangle shaped ones, to allow for zero ohm resitors to be used as bridges.

Severity level

This is medium priority because the functional and optical benefit is large.

# Modify header pins to solder jumpers ## Problem environment Most of the jumper connectors are designed for header pins, useful in prototype testing. As design stabilises, header pins are less useful and design benefits from solder jumpers instead. ## Steps to reproduce 1. Observe the layout 1. Search for jumpers 1. Examine the bill of materials ## Expected result * **JP1:** Solder jumper (no bridge) * **JP2:** Solder jumper (bridged 1,2) * **JP3:** Solder jumper (bridged 1,2) * **J1:** Solder jumper (3-way bridged 2,3) ## Actual result * **JP1:** Header pins * **JP2:** Header pins * **JP3:** Header pins * **J1:** Header pins ## Note Replace with **oval shaped solder jumpers** rather than triangle shaped ones, to allow for zero ohm resitors to be used as bridges. ## Severity level This is **medium priority** because the functional and optical benefit is large.
Michael Schloh von Bennewitz dodano etykietę
enhancement
4 lat temu
Michael Schloh von Bennewitz dodaje to do kamienia milowego Final schematic and layout design 4 lat temu
Michael Schloh von Bennewitz skomentował(-a) 4 lat temu
Właściciel

Resolved by 7e32c82.

Resolved by 7e32c82.
Zaloguj się, aby dołączyć do tej rozmowy.
Brak kamienia milowego
Brak przypisanych
Uczestnicy 1
Termin realizacji

Brak ustawionego terminu realizacji.

Zależności

To zgłoszenie nie ma w tej chwili żadnych zależności.

Ładowanie…
Anuluj
Zapisz
Nie ma jeszcze treści.