#88 Jumper between C22 and PA9 is missing

Geschlossen
vor 4 Jahren von Michael Schloh von Bennewitz geöffnet · 1 Kommentare

Jumper between C22 and PA9 is missing

Problem environment

Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC.

Steps to reproduce

  1. Refer to the schematic
  2. Examine PA9, VCC, and C22
  3. Determine the cases of powering RF1 and XC1

Expected result

C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09.

Actual result

C22 is fix bridged to PA09, and there is no jumper to VCC.

Workaround

Solder a wire from C22 to JP1.

Notice

The jumper should be a solder jumper with three pads and VCC to C22 default connected.

Severity level

This is medium priority because project deliverables require stable firmware, which benefits from the jumper strategy.

# Jumper between C22 and PA9 is missing ## Problem environment Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC. ## Steps to reproduce 1. Refer to the schematic 1. Examine PA9, VCC, and C22 1. Determine the cases of powering RF1 and XC1 ## Expected result C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09. ## Actual result C22 is fix bridged to PA09, and there is no jumper to VCC. ## Workaround Solder a wire from C22 to JP1. ## Notice The jumper should be a solder jumper with three pads and VCC to C22 default connected. ## Severity level This is **medium priority** because project deliverables require stable firmware, which benefits from the jumper strategy.
Michael Schloh von Bennewitz fügte das
enhancement
Label vor 4 Jahren hinzu
Michael Schloh von Bennewitz hat diesen Issue vor 4 Jahren zum Final schematic and layout design Meilenstein hinzugefügt
Michael Schloh von Bennewitz hat den Titel von Jumper between C22 and PA3 is missing zu Jumper between C22 and PA9 is missing vor 4 Jahren geändert
Michael Schloh von Bennewitz hat vor 4 Jahren kommentiert
Besitzer

Resolved in 7da0bfb.

Resolved in 7da0bfb.