Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC.
Steps to reproduce
Refer to the schematic
Examine PA9, VCC, and C22
Determine the cases of powering RF1 and XC1
Expected result
C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09.
Actual result
C22 is fix bridged to PA09, and there is no jumper to VCC.
Workaround
Solder a wire from C22 to JP1.
Notice
The jumper should be a solder jumper with three pads and VCC to C22 default connected.
Severity level
This is medium priority because project deliverables require stable firmware, which benefits from the jumper strategy.
# Jumper between C22 and PA9 is missing
## Problem environment
Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC.
## Steps to reproduce
1. Refer to the schematic
1. Examine PA9, VCC, and C22
1. Determine the cases of powering RF1 and XC1
## Expected result
C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09.
## Actual result
C22 is fix bridged to PA09, and there is no jumper to VCC.
## Workaround
Solder a wire from C22 to JP1.
## Notice
The jumper should be a solder jumper with three pads and VCC to C22 default connected.
## Severity level
This is **medium priority** because project deliverables require stable firmware, which benefits from the jumper strategy.
Jumper between C22 and PA9 is missing
Problem environment
Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC.
Steps to reproduce
Expected result
C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09.
Actual result
C22 is fix bridged to PA09, and there is no jumper to VCC.
Workaround
Solder a wire from C22 to JP1.
Notice
The jumper should be a solder jumper with three pads and VCC to C22 default connected.
Severity level
This is medium priority because project deliverables require stable firmware, which benefits from the jumper strategy.