#88 Jumper between C22 and PA9 is missing

닫힘
Michael Schloh von Bennewitz4 년 전을 오픈 · 1개의 코멘트

Jumper between C22 and PA9 is missing

Problem environment

Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC.

Steps to reproduce

  1. Refer to the schematic
  2. Examine PA9, VCC, and C22
  3. Determine the cases of powering RF1 and XC1

Expected result

C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09.

Actual result

C22 is fix bridged to PA09, and there is no jumper to VCC.

Workaround

Solder a wire from C22 to JP1.

Notice

The jumper should be a solder jumper with three pads and VCC to C22 default connected.

Severity level

This is medium priority because project deliverables require stable firmware, which benefits from the jumper strategy.

# Jumper between C22 and PA9 is missing ## Problem environment Errata and the datasheet for the Microchip based sendcomm design specifies powering the XC1 oscillator and RF1 switch from the SAMR34 PA9 rather than VCC. ## Steps to reproduce 1. Refer to the schematic 1. Examine PA9, VCC, and C22 1. Determine the cases of powering RF1 and XC1 ## Expected result C22 is only powered from a programmable power source, like PA09. A jumper exists to bridge C22 to VCC, or bridge C22 to PA09. ## Actual result C22 is fix bridged to PA09, and there is no jumper to VCC. ## Workaround Solder a wire from C22 to JP1. ## Notice The jumper should be a solder jumper with three pads and VCC to C22 default connected. ## Severity level This is **medium priority** because project deliverables require stable firmware, which benefits from the jumper strategy.
Michael Schloh von Bennewitz added the
enhancement
label 4 년 전
Michael Schloh von Bennewitz Final schematic and layout design 4 년 전 마일스톤을 추가하였습니다.
Michael Schloh von Bennewitz changed title from Jumper between C22 and PA3 is missing to Jumper between C22 and PA9 is missing 4 년 전
Michael Schloh von Bennewitz 코멘트됨, 4 년 전
소유자

Resolved in 7da0bfb.

Resolved in 7da0bfb.
로그인하여 이 대화에 참여
담당자 없음
참여자 1명
마감일

마감일이 설정되지 않았습니다.

의존성

이 이슈는 어떠한 의존성도 가지지 않습니다.

불러오는 중...
취소
저장
아직 콘텐츠가 없습니다.