#104 AE5 pad 1 has unconnected vias

Cerrada
abierta hace 4 años por Michael Schloh von Bennewitz · 1 comentarios

AE5 pad 1 has unconnected vias

Problem environment

Antenna connectors are routed appropriately, but if vias are left unconnected it should be corrected.

Steps to reproduce

  1. Refer to the layout
  2. Examine AE5
  3. Search vias

Expected result

All vias are connected according to schematic.

Actual result

Two vias on pad 1 are not connected, and should be removed.

Severity level

This is low priority because the unconnected vias do not impair function.

# AE5 pad 1 has unconnected vias ## Problem environment Antenna connectors are routed appropriately, but if vias are left unconnected it should be corrected. ## Steps to reproduce 1. Refer to the layout 1. Examine AE5 1. Search vias ## Expected result All vias are connected according to schematic. ## Actual result Two vias on pad 1 are not connected, and should be removed. ## Severity level This is **low priority** because the unconnected vias do not impair function.
Michael Schloh von Bennewitz ha añadido la etiqueta
bug
hace 4 años
Michael Schloh von Bennewitz ha añadido esto al hito Final schematic and layout design hace 4 años ' issues.change_milestone_at=`modificó el hito de %!s(MISSING) a %!s(MISSING) %!s(MISSING)

Resolved by b969424.