#104 AE5 pad 1 has unconnected vias

닫힘
Michael Schloh von Bennewitz4 년 전을 오픈 · 1개의 코멘트

AE5 pad 1 has unconnected vias

Problem environment

Antenna connectors are routed appropriately, but if vias are left unconnected it should be corrected.

Steps to reproduce

  1. Refer to the layout
  2. Examine AE5
  3. Search vias

Expected result

All vias are connected according to schematic.

Actual result

Two vias on pad 1 are not connected, and should be removed.

Severity level

This is low priority because the unconnected vias do not impair function.

# AE5 pad 1 has unconnected vias ## Problem environment Antenna connectors are routed appropriately, but if vias are left unconnected it should be corrected. ## Steps to reproduce 1. Refer to the layout 1. Examine AE5 1. Search vias ## Expected result All vias are connected according to schematic. ## Actual result Two vias on pad 1 are not connected, and should be removed. ## Severity level This is **low priority** because the unconnected vias do not impair function.
Michael Schloh von Bennewitz added the
bug
label 4 년 전
Michael Schloh von Bennewitz Final schematic and layout design 4 년 전 마일스톤을 추가하였습니다.
Michael Schloh von Bennewitz 코멘트됨, 4 년 전
소유자

Resolved by b969424.