#104 AE5 pad 1 has unconnected vias

Suljettu
4 vuotta sitten avasi Michael Schloh von Bennewitz · 1 kommenttia

AE5 pad 1 has unconnected vias

Problem environment

Antenna connectors are routed appropriately, but if vias are left unconnected it should be corrected.

Steps to reproduce

  1. Refer to the layout
  2. Examine AE5
  3. Search vias

Expected result

All vias are connected according to schematic.

Actual result

Two vias on pad 1 are not connected, and should be removed.

Severity level

This is low priority because the unconnected vias do not impair function.

# AE5 pad 1 has unconnected vias ## Problem environment Antenna connectors are routed appropriately, but if vias are left unconnected it should be corrected. ## Steps to reproduce 1. Refer to the layout 1. Examine AE5 1. Search vias ## Expected result All vias are connected according to schematic. ## Actual result Two vias on pad 1 are not connected, and should be removed. ## Severity level This is **low priority** because the unconnected vias do not impair function.
Michael Schloh von Bennewitz added the
bug
label 4 vuotta sitten
Michael Schloh von Bennewitz added this to the Final schematic and layout design milestone 4 vuotta sitten

Resolved by b969424.

Resolved by b969424.